About the BFG1F5040T3NOV Gas Water Heater
The BFG1F5040T3NOV Gas Water Heater is an atmospheric vent gas storage water heater with a larger tank than the 40-gallon variants, a glass-lined tank and a temperature and pressure relief valve. A heater that suddenly runs out of hot water faster than it used to may have a broken dip tube, which lets cold water mix at the top of the tank instead of entering at the bottom.
Calls on this model cover short hot water supply at peak demand, a deteriorating dip tube, draft hood spillage in a tight utility room and a weeping relief valve. That valve should never be capped or plugged: it is a safety device, and a discharging valve means either high pressure in the system or a valve at the end of its life.
What we check on a BFG1F5040T3NOV Gas Water Heater visit
- Dip tube condition when hot water runs short at peak demand
- Draft hood spillage in a tight utility room
- Relief valve weeping
Key features
- Atmospheric vent gas storage water heater
- Larger tank capacity than the 40-gallon variants
- Temperature and pressure relief valve fitted
- Glass-lined tank
The model number is on the data label: inside the door frame, on the drawer edge or behind the kick plate. We are an independent repair company, not affiliated with Whirlpool Corporation.
Other Whirlpool water heater models
Water HeaterBFG1F4034T3NOVShort gas storage water heater
Water HeaterBFG1H5040T3NOVAtmospheric vent gas water heater
Water HeaterE2F40RD045Dual element electric water heater
Water HeaterES40R123-45DElectric tank water heater
Water HeaterES40R92-45DLegacy electric water heater
Water HeaterES50R123-45DLarge electric storage water heater
Water HeaterE2F50HD045V Electric Water HeaterDual element electric water heater
Water HeaterFG1H5040T3NOV Gas Water HeaterAtmospheric vent gas water heaterBFG1F5040T3NOV Gas Water Heater questions
Why does my BFG1F5040T3NOV run out of hot water faster now?
A broken dip tube can let cold water mix at the top of the tank. The tank is checked for that, along with burner output and sediment, before capacity is blamed.
The relief valve is dripping. Can I cap it?
Never. It is a safety device, and a discharging valve means high pressure or a valve nearing the end of its life. Both need a technician.