29-inch gas dryer. Service for this model across Tampa Bay.

- Model
- WGD5510VQ
- Type
- 29-inch gas dryer
- Brand
- Whirlpool
About the WGD5510VQ
The WGD5510VQ is a 29-inch Whirlpool gas dryer with the endings WGD5510VQ0 and WGD5510VQ1. It needs a gas line, a regular outlet and an exhaust duct to the outdoors.
A dryer that runs but stays cold generates the most calls for this type of machine, so the heat path is tested in a set order: supply and shutoff, then the igniter, then the gas valve coils, then the thermostats. A blower housing clogged with lint also cuts the hot air reaching the drum, so it is opened and cleaned. If the selector or start control does not respond, we test it before blaming the motor.
What we check on a WGD5510VQ visit
- Gas supply, shutoff, igniter, valve coils and thermostats in order
- Blower housing lint and vent restriction
- Selector or start switch response and drum belt wear
Key features
- 29-inch body
- Gas burner heat
- Revision endings 0 and 1
The model number is on the data label: inside the door frame, on the drawer edge or behind the kick plate. We are an independent repair company, not affiliated with Whirlpool Corporation.
Whirlpool dryer codes
Codes listed for Whirlpool dryers. Which ones a unit can show depends on its control board, so we confirm by the full model number.
Other Whirlpool dryer models
WGD5510VQ questions
The dryer runs but my clothes stay cold. Where does the visit begin?
With confirming the gas is on, then watching the igniter and valve. If the igniter glows with no flame, the valve coils are next, followed by the thermostats.
What if the selector knob does nothing?
The switch behind it and the wiring to the control are tested. A worn switch costs far less to replace than a new dryer.